NEMA and UL are standards writing organizations. The material which follows is not intended as a complete representation the National Electrical Manufacturers Association (NEMA), or Underwriters Laboratories, Inc. (UL) electrical enclosure standards. NEMA, UL, or Clark Wire & Cable shall not incur any obligation or liability for damages from the interpretation of this material. The following information is a portion of NEMA ratings that pertain to many of the enclosures sold by Clark Wire & Cable.

TYPE 3R 


National Electrical Manufacturers Association (NEMA) Vector Logo - (.SVG +  .PNG) - GetVectorLogo.Com Enclosures constructed for either indoor or outdoor use to provide a degree of protection to personnel against access to hazardous parts; to provide a degree of protection of the equipment inside the enclosure against ingress of solid foreign objects (falling dirt); to provide a degree of protection with respect to harmful  effects on the equipment due to the ingress of water (rain, sleet, snow); and that will be undamaged by the external formation of ice on the enclosure. Example: HMD-EJ12126

   Look for the UL safety Mark before you buy | UL Solutions
 
Indoor or outdoor use to provide a degree of protection to personnel against incidental contact with the enclosed equipment; to provide a degree of protection against falling dirt, rain, sleet, and snow; and that will be undamaged by the external formation of ice on the enclosure.

TYPE 4


National Electrical Manufacturers Association (NEMA) Vector Logo - (.SVG +  .PNG) - GetVectorLogo.Com Indoor or outdoor use to provide a degree of protection to personnel against access to hazardous parts; to provide a degree of protection of the equipment inside the enclosure against ingress of solid foreign objects (falling dirt and windblown dust); to provide a degree of protection with respect to harmful effects on the equipment due to the ingress of water (rain, sleet,
snow, splashing water, and hose directed water);  that provides an additional level of protection against corrosion; and that will be undamaged by the external formation of ice on the enclosure.
 Look for the UL safety Mark before you buy | UL Solutions
Indoor or outdoor use to provide a degree of protection to personnel against incidental contact with the enclosed equipment; to provide a degree of protection against falling dirt, rain, sleet, snow, windblown dust, splashing water, and hose-directed water; and that will be undamaged by the external formation of ice on the enclosure. 

TYPE 12


National Electrical Manufacturers Association (NEMA) Vector Logo - (.SVG +  .PNG) - GetVectorLogo.Com Constructed (without knockouts) for indoor use to provide a degree of protection to personnel against access to hazardous parts; to provide a degree of protection of the equipment inside the enclosure against ingress of solid foreign objects (falling dirt and circulating dust, lint, fibers, and flyings); and to provide a degree of protection with respect to harmful effects
on the equipment due to the ingress of water (dripping and light splashing). 
 Look for the UL safety Mark before you buy | UL Solutions
Constructed (without knockouts) for indoor use to provide a degree of protection to personnel against incidental contact with the enclosed equipment; to provide a degree of protection against falling dirt; against circulating dust, lint, fibers, and flyings; against dripping and light splashing of non-corrosive liquids; and against light splashing and consequent seepage of oil and non-corrosive coolants.

TYPE 13


National Electrical Manufacturers Association (NEMA) Vector Logo - (.SVG +  .PNG) - GetVectorLogo.Com Indoor use to provide a degree of protection to personnel against access to hazardous parts; to provide a degree of protection of the equipment inside the enclosure against ingress of solid foreign objects (falling dirt and circulating dust, lint, fibers, and flyings); to provide a degree of protection with respect to harmful effects on the equipment due to the ingress of
water (dripping and light splashing); and to provide a degree of protection against the spraying, splashing, and seepage of oil and non-corrosive coolants.
 Look for the UL safety Mark before you buy | UL Solutions
Indoor use to provide a degree of protection to personnel against incidental contact with the enclosed equipment; to provide a degree of protection against falling dirt; against circulating dust, lint, fibers, and flyings; and against the spraying, splashing, and seepage of water, oil, and non-corrosive coolants.