Plenum Rated Cat5E 350MHz UTP Cable

 

CN424C5P

Enhanced 350 MHz Bandwidth - provides addtional bandwidth for high data rate applications

ETL Verified to TIA-568-C.2 - verified to meet or exceed TIA standards for Cat5E cable

ETL Verified to ISO/IEC 11801 - verified to meet or exceed ISO/IEC standards for Cat5E cable

1000 Mbps Gigabit Ethernet - delivers precision electrical performance for 10Gbs data transmission

UL Rated Plenum CMP - UL and CSA rated for installation in most plenum environments

The CN424C5P is an enhanced plenum rated Category 5E for networking and data applications. Constructed from four precision twisted pairs, the CN424C5P is tested to meet or exceed TIA-568-C.2 and ISO/IEC 11801 specifications. UL rated plenum Type CMP and CSA FT-6, the CN424C5P is suitable for installation in most permanent installation environments.

 

Materials & Dimentions

Conductors

(8) 24AWG Solid BC (configured as four pairs)

Insulation

FEP, .008" wall

Insulation Color Code

Pair 1: Blue & White w/ Blue Stripe

Pair 2: Orange & White w/ Orange Stripe

Pair 3: Green & White w/ Green Stripe

Pair 4: Brown & White w/ Brown Stripe

Jacket

Plenum PVC

Overall Diameter

.200"

 

Cross Sectional Diagram

 

Mechanical Characteristics

Operating Temperature Weight Agency Listing
-20degC to +75degC

25 lbs/Mft

CMP C(ETL) FT-6

ETL Listed & Verified

 

Electrical Characteristics

DCR DCR Unbalance Characteristic Impedance Skew Capacitance
9.38 Ω/100m

5%

100 Ω (+/-15)

40 ms/100m

(max.)

5.6 nF/100m (mutual)

330 pF/100m (pair-to-pair ground unblanced)

 

Frequency (MHz) 1 4 8 10 16 20 25 31.3 62.5 100 155 200 250 300 350
Insertion Loss(max.)
2.0 4.1 5.8 6.5 8.2 9.3 10.4 11.7 17.0 22.0 28.1 32.4 38.9 41.0 44.9
(nom.)
1.8 3.6 5.1 5.8 7.4 8.2 9.3 10.5 14.9 19.2 24.2 27.3 30.9 34.1 37.8
Return Loss(max.)
23.0 23.0 24.5 25.0 25.0 25.0 24.3 23.6 21.5 20.1 18.8 18.0 17.5 16.8 16.3
(nom.)
38.6 39.8 38.2 38.0 37.4 36.8 35.2 33.3 32.2 31.3 29.8 28.5 27.3 25.6 23.2
NEXT(min.)
70.3 61.2 56.8 55.3 52.3 50.8 49.3 47.9 43.4 40.3 37.4 35.7 34.8 33.1 32.1
(nom.)
79.4 69.9 61.9 62.4 57.8 56.4 56.3 53.8 49.8 47.5 45.1 43.3 41.4 40.2 39.0
PS-NEXT(min.)
68.3 59.3 54.8 53.5 50.3 48.8 47.3 45.9 41.4 38.3 35.4 33.7 32.5 31.1 30.1
(nom.)
76.9 67.4 59.4 59.9 55.2 53.8 53.6 51.1 47.4 45.0 42.6 40.2 39.0 37.7 36.5
ELFEXT(min.)
63.8 51.7 45.7 43.8 39.7 39.7 35.8 33.9 27.8 23.8 19.9 17.7 17.1 16.7 16.0
(nom.)
71.3 59.4 53.2 50.5 47.0 45.0 43.3 41.3 35.8 31.3 27.5 24.7 22.2 20.5 19.4
PS-ELFEXT(min.)
60.8 48.7 42.7 40.8 36.7 34.7 32.8 30.9 24.8 20.8 16.9 14.7 14.0 13.5 12.8
(nom.)
70.6 58.7 51.1 49.7 45.1 43.6 42.0 40.5 34.5 30.3 26.9 24.5 22.5 20.7 19.6
ACR(min.)
68.2 57.2 51.0 48.8 43.0 41.5 38.9 36.5 26.4 18.3 10.0 5.0 0.0 - -
(nom.)
77.6 66.3 59.8 56.6 53.0 50.5 47.0 43.3 35.0 26.2 20.9 16.0 10.6 6.1 1.2
PS-ACR(min.)
66.3 55.2 49.0 47.0 42.1 39.5 36.9 34.2 24.4 16.3 7.3 2.0 - - -
(nom.)
75.0 63.5 56.9 53.7 47.4 45.0 43.7 40.0 31.2 24.2 15.9 10.0 4.0 -1.3 -6.4

All values listed in above table are dB/100m of cable.

 




 
 