Amphenol BNC Strip Dimensions

    Outer ferrule Bushing*

Male

contact

Plug body

assembly

Female

contact

Jack body

assembly

   

ConnectorType 75 BNC Plug

 
Amphenol
No.
Cable Type Stripping Dimesions
a
b
c
BNC-112119 Clark RG59B/U .593 .250 .156
BNC-112507 CV7559, 500 Series .593 .250 .156
BNC-112544 CV7559-Plen .593 .250 .156
BNC-112509 Clark CV752 .593 .250 .156
BNC-112565 Clark RG6SD .593 .250 .156



 

Assembly Instructions For 3 Piece BNC Connectors

 
 

   

    Outer ferrule
 Bushing*

Male

contact

Plug body

assembly

Female

contact

Jack body

assembly

                                                                           * for use on RG-62, 71, 210 cable only



ConnectorType: 75 BNC Plug

Connex / ADC No.

& Clark Cable No.

Hex Crimp Data
Contact For Connex/ADC
Cavity for
Outer Ferrule
Die Set for
Tool-1
Tool No.
BNC-112119 / BNC-2-N
Clark   RG59B/U
     .068 .255 DIE-1 TOOL-1
.042
BNC-112507 / BNC-1-N
Clark CV7559, RCC Series
     .068 .255 DIE-1 TOOL-1
.042
BNC-112509 / BNC-4-N
Clark CV752
      .068 .324 DIE-1 TOOL-1
.042
BNC-112521 / BNC-13
DSM1
      .068 .178 DIE-8 TOOL-8
.042
BNC-112521 / BNC-8
RG6SD
     .068 .278 DIE-8 TOOL-8
.042


  


Step 1 :
Strip cable jacket, braid, and dielectric to dimensions in table below.

[for RG-62,71, & 210/U cables, trim an additional .039"(1.0mm) of insulation off center conductor and add bushing]

Slide outer ferrule onto cable as shown.

Important: Do not nick braid, dielectric, and center conductor.

All cuts are to be sharp and square.
  

 

  Strip Dimensions For Connex BNC's                              Strip Dimensions For ADC BNC 's
 

              a   .593 (15.1)
              b
   .250 (6.4)
              c
  .156 (4.0)

            

             Ferrule

        


                    

 

                                          


                                                                           
 

For  RG-174, 179, 187, 188, 316/U cables only, slit jacket back .100"(2.5mm) as shown.

Before attaching center contact TFE sleeve (not shown) over cable dielectric and under braid.

For 31-71016, before attaching center contact. Slide metal spacer/TFE sleeve (not shown)

over cable dielectric and under braid.

The center contact should butt against the dielectric and TFE sleeve.

     

  
Step 2

Flare slightly end of cable braid as shown to facilitate insertion of inner ferrule.

Important: Do not comb out braid.
Place contact on cable center conductor so that it butts against cable dielectric.

Crimp contact in place using Die Set Cavity indicated in table above.

When using RG-62, 71, 210, install bushing over center conductor before installing contact.

    
       contact must butt against cable dielectric
  
       outer ferrule       
       should butt here          cable dielectric must butt insulator
 

 
 
 